Ten amps continuous in a sealed automotive housing is a thermal case study: the forward-drop loss at temperature, the junction calculation, and the copper-and-housing countermeasures. This guide walks the worked case from loss to verification, with the parameters to confirm from the official datasheet.
(Last modified date: August 31, 2026)
Estimate the loss at the hot VF, iterate the junction temperature through the thermal chain (TJ = TC + PD × RθJC), size the copper, vias and housing to close it, then confirm with the case-temperature measurement on the prototype.
Setting Up the Problem: 10 A Continuous in a Sealed Housing
The case: a 10 A rectifier in a sealed automotive module, no airflow, worst ambient near the vehicle’s high end. The design question is whether the junction stays inside its limit with margin, and the answer starts with the loss at the working temperature — not the 25 °C datasheet point. The sealed housing sets the thermal chain: the junction-to-case resistance, the pad-and-board path, and the housing-to-ambient step, each contributing to the junction temperature the design must close.
Loss First: Estimating VF Loss at Temperature
The forward-drop loss is the first term: at 10 A, a 0.7 V drop is about 7 W, and the drop’s temperature behavior — read from the datasheet curve at the working junction — changes the number. The loss estimate uses the maximum VF at the operating temperature, not the typical at 25 °C, and the leakage term at the hot junction joins the budget.
Junction Temperature Walkthrough
| Step | Value |
|---|---|
| Current | 10 A |
| VF (maximum at operating temperature) | 0.7–0.9 V class |
| Forward loss | ~7–9 W |
| RθJC (package) | Confirmed from datasheet |
| Case-to-ambient resistance | Board, housing, and ambient |
| Junction temperature | TC + (PD × RθJC), iterated |
The walkthrough is the method: compute the loss at the assumed junction, walk the thermal chain, read the new junction, and iterate until it settles. The final number is confirmed by the case-temperature measurement on the prototype — a single-pass 25 °C calculation is an estimate, not a thermal design.
The Measurement Protocol in the Sealed Housing. The thermocouple is bonded to the case near the die, the module runs at the rated load in the sealed housing at the maximum ambient, and the case temperature is recorded after the steady-state criterion is met rather than after a fixed soak time. The measured case, the calculated junction, and the margin are the record, and the same protocol is re-run when the housing, the board, or the duty changes.
Parameters to Confirm With the Official Datasheet
The worked case’s inputs are placeholders until the datasheet provides the real values: the maximum VF at the operating current and temperature, the leakage at the working reverse voltage, the RθJC with the mounting assumption, and the derating curve. None is assumed; the supplier’s datasheet is the contract, and the AWSS10H60’s full specification is confirmed through Good-Ark sales.
Thermal Countermeasures: Copper, Vias, Housing
The countermeasures follow the chain: the board copper and the via grid carry the heat from the exposed pad, the housing’s material and the interface spread it, and the ambient step is improved by any airflow the design can create. The exposed-pad footprint rules and the thermal design method own the details; the worked case shows that the loss, the chain, and the countermeasures are one calculation.
The countermeasures are ranked by their effect on the junction: copper and vias first, the housing’s interface second, and any airflow third, with each improvement measured and recorded. The thermal camera on the prototype shows the heat distribution, and the case-temperature measurement closes the margin. The worked case closes when the measured junction sits inside the margin, and the record is the design’s thermal proof.
Engineering note: the worked case uses class-typical VF values and a placeholder RθJC until the official datasheet confirms the AWSS10H60’s parameters; the iteration and the prototype measurement follow the thermal design method, and no value is assumed before the datasheet is received.
Frequently Asked Questions
Why does the loss use the hot VF?
Because the drop’s temperature behavior is read at the working junction, and the maximum at temperature is the design’s input — the 25 °C typical is an estimate, not the thermal result.
How is the junction calculated?
TJ = TC + (PD × RθJC), with the case set by the board, housing, and ambient, iterated until the temperature settles and confirmed by measurement.
What does the sealed housing change?
The case-to-ambient resistance is the housing’s and the board’s — no airflow means the chain carries the whole story.
What are the countermeasures?
Copper area, thermal vias, the housing’s material and interface, and any airflow — each improving one step of the chain.
What must the datasheet confirm?
The maximum VF at temperature, the leakage, the RθJC with the mounting, and the derating curve — none assumed from the site’s published set.
Related Articles
- AWSS10H60: 10 A, 60 V Schottky for High-Current Automotive Lighting
- Solder Joint Reliability for TO-277 in Automotive LED Modules
- Surge Damage in Power Supplies: Reading the Evidence
- When TVS Protection Fails: Layout, Rating, and Repetition Mistakes
- Power Semiconductor Sourcing Strategy: Second Sources and Long-Term Supply
Sources
- Good-Ark – AWSS10H60 Product Page
- Good-Ark – Schottky Rectifier Diodes
- Good-Ark – New Release (Automotive Applications)
- Good-Ark – Contact