Staying Inside the SOA: Reading MOSFET Safe-Operating-Area Curves for Repetitive Pulses
The safe-operating-area curve is the MOSFET datasheet page that looks like a simple V-I plot and behaves like a set of stacked limits. A single DC operating point sits inside a thermal box; a pulse train can reach far higher current but only for a limited time; and the slope of the boundary lines changes … Read more